CLS-Series Separate Skid Mounted
Closed Circuit Cooling Towers
Whaley Products’ CLS-Series Closed Circuit Cooling Tower Systems can serve any industry that needs their water circuits clean at all times. Utilizing WPI’s proven WP-Series Cooling Towers in a closed loop circuit with stainless steel heat exchangers, flushable stainless steel strainers, and a recirculation cooling tower pumps is the strenght of the product line. The CLS-Series cooling towers require basin heaters in cold seasons if temperatures go below freezing. If your company wants the security of knowing your cooling tower will never freeze up, check out our CLIO-Series Cooling Tower Systems. They include an outdoor cooling tower and indoor pump-tank/heat transfer skid. WPI believe that our closed loop towers provide a low-maintenance, cost effective, long lasting, durable cooling system that can save you time and money
Model
|
Tower Tons / KW
|
Flow: GPM
|
HX Type
|
PUMP
|
Strainer In/Out
|
Strainer Max Flow
|
CLS650-10 |
10 Ton/44KW
|
30 GPM
|
PHX
|
1.0 HP, #11, 4.88″
|
2″ NPT Bottom
|
100 gpm
|
CLS650-15 |
15 Ton/66KW
|
45 GPM
|
PHX
|
1.5 HP , #126, 5.25″
|
2″ NPT Bottom
|
100 gpm
|
CLS850-20 |
20 Ton/88KW
|
60 GPM
|
PHX
|
2.0 HP, # 16, 4.75″
|
2″ NPT Bottom
|
100 gpm
|
CLS850-25 |
25 Ton/110KW
|
75 GPM
|
PHX
|
2.0 HP, #16, 4.88″
|
2″ NPT Bottom
|
100 gpm
|
CLS1250-30 |
30 Ton/132KW
|
90 GPM
|
PHX
|
3.0 HP, #17, 4.75″
|
2″ NPT Bottom
|
100 gpm
|
CLS1250-40 |
40 Ton/176KW
|
120 GPM
|
PHX
|
3.0 HP, #17, 4.75″
|
3″ NPT Bottom
|
200 gpm
|
CLS1550-50 |
50 Ton/220KW
|
150 GPM
|
PFHX
|
5.0 HP, #17, 5.25″
|
3″ NPT Bottom
|
200 gpm
|
CLS1550-75 |
75 Ton/330KW
|
225 GPM
|
PFHX
|
7.5 HP, #15, 4.88″
|
4″ flange side
|
350 gpm
|
CLS1850-100 |
100 Ton/440KW
|
300 GPM
|
PFHX
|
10 HP, #15, 5.25″
|
4″ flange side
|
350 gpm
|
CLS1850-125 |
125 Ton/550KW
|
375 GPM
|
PFHX
|
10 HP, #56F, 5.00″
|
4″ flange side
|
350 gpm
|
CLS2-1850-200 |
200 Ton/880KW
|
600 GPM
|
PFHX
|
20 HP, #57, 5.50″
|
6″ flange side
|
750 gpm
|
CLS2-1850-250 |
250 Ton/1100KW
|
750 GPM
|
PFHX
|
20 HP, #57, 5.50″
|
6″ flange side
|
750 gpm
|
CLS3-1850-300 |
300 Ton/1320KW
|
900 GPM
|
PFHX
|
20 HP, #96, 8.90″
|
8″ flange side
|
1300 gpm
|
CLS3-1850-375 |
375 Ton/1650KW
|
1125 GPM
|
PFHX
|
25 HP, #96, 9.38″
|
8″ flange side
|
1300 gpm
|
CLS4-1850-400 |
400 Ton/1760KW
|
1200 GPM
|
PFHX
|
25 HP, #96, 9.38″
|
8″ flange side
|
1300 gpm
|
CLS4-1850-500 |
500 Ton/2200KW
|
1500 GPM
|
PFHX
|
30 HP, #96, 10.0″
|
10″ flange side
|
2000 gpm
|
3 GPM / ton from 95°F to 85°F (at 78°F wet bulb).
Construction material details:
Non-corrosive FRP(Fiberglass Reinforced Polyester) marine grade resins
Surface layer containing pigmented gel coat
Ultraviolet (UV) inhibitor included as an additive to the composite matrix.
Accu-Pac cross fluted fill pack:
Improves water distribution by splitting water stream 8 times in a 12″ vertical path as it descends through the fill pack
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC
Accu-Pac counterflow cellular drift eliminators
High surface area provides maximum performance at minimum pressure drop
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC
Cellular Inlet Louvers installed:
Improve air flow into cooling tower
Prevent debris from entering
Eliminate water splash-out that can cause icing, water treatment chemical loss
Restricts amount of sunlight into cooling tower impeding algae growth
Reduce noise from tower
Improve tower’s appearance
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC
Lightweight ABS plastic non-clogging Dek-Spray nozzles
serviceable at temperatures up to 180F/82C
Results in less system weight & piping cost
Steel Tower platform with fork slots
4″ C-Channel
Sheered sheet metal cover with cut-out for bottom tower drain
Painted with gray Macropoxy 646 Fast Cure Epoxy (high solids, high build, polyamide epoxy designed to protect steel and concrete in industrial exposures)
Side or bottom outlet drain
Location and size of outlet fitting determined according to your requirements
Schedule 80 distribution header |
PVC inlet flange |
½” automatic water makeup |
Stainless steel hardware |
Glossy white color |
Direct drive fan motors |
Axial fan blades |