CLS-Series Separate Skid Mounted

Closed Circuit Cooling Towers

Whaley Products’ CLS-Series Closed Circuit Cooling Tower Systems can serve any industry that needs their water circuits clean at all times. Utilizing WPI’s proven WP-Series Cooling Towers in a closed loop circuit with stainless steel heat exchangers, flushable stainless steel strainers, and a recirculation cooling tower pumps is the strenght of the product line. The CLS-Series cooling towers require basin heaters in cold seasons if temperatures go below freezing. If your company wants the security of knowing your cooling tower will never freeze up, check out our CLIO-Series Cooling Tower Systems. They include an outdoor cooling tower and indoor pump-tank/heat transfer skid. WPI believe that our closed loop towers provide a low-maintenance, cost effective, long lasting, durable cooling system that can save you time and money

clsseriesanim1

(Click to enlarge photos)

2ea1850s closedloopskid1 closedloopskid2 panelcl

CLS-Series Capacities Available

Model
Tower Tons / KW
Flow: GPM
HX Type
PUMP
Strainer In/Out
Strainer Max Flow
CLS650-10
10 Ton/44KW
30 GPM
PHX
1.0 HP, #11, 4.88″
2″ NPT Bottom
100 gpm
CLS650-15
15 Ton/66KW
45 GPM
PHX
1.5 HP , #126, 5.25″
2″ NPT Bottom
100 gpm
CLS850-20
20 Ton/88KW
60 GPM
PHX
2.0 HP, # 16, 4.75″
2″ NPT Bottom
100 gpm
CLS850-25
25 Ton/110KW
75 GPM
PHX
2.0 HP, #16, 4.88″
2″ NPT Bottom
100 gpm
CLS1250-30
30 Ton/132KW
90 GPM
PHX
3.0 HP, #17, 4.75″
2″ NPT Bottom
100 gpm
CLS1250-40
40 Ton/176KW
120 GPM
PHX
3.0 HP, #17, 4.75″
3″ NPT Bottom
200 gpm
CLS1550-50
50 Ton/220KW
150 GPM
PFHX
5.0 HP, #17, 5.25″
3″ NPT Bottom
200 gpm
CLS1550-75
75 Ton/330KW
225 GPM
PFHX
7.5 HP, #15, 4.88″
4″ flange side
350 gpm
CLS1850-100
100 Ton/440KW
300 GPM
PFHX
10 HP, #15, 5.25″
4″ flange side
350 gpm
CLS1850-125
125 Ton/550KW
375 GPM
PFHX
10 HP, #56F, 5.00″
4″ flange side
350 gpm
CLS2-1850-200
200 Ton/880KW
600 GPM
PFHX
20 HP, #57, 5.50″
6″ flange side
750 gpm
CLS2-1850-250
250 Ton/1100KW
750 GPM
PFHX
20 HP, #57, 5.50″
6″ flange side
750 gpm
CLS3-1850-300
300 Ton/1320KW
900 GPM
PFHX
20 HP, #96, 8.90″
8″ flange side
1300 gpm
CLS3-1850-375
375 Ton/1650KW
1125 GPM
PFHX
25 HP, #96, 9.38″
8″ flange side
1300 gpm
CLS4-1850-400
400 Ton/1760KW
1200 GPM
PFHX
25 HP, #96, 9.38″
8″ flange side
1300 gpm
CLS4-1850-500
500 Ton/2200KW
1500 GPM
PFHX
30 HP, #96, 10.0″
10″ flange side
2000 gpm

UNIT CAPACITY RATING:
3 GPM / ton from 95°F to 85°F (at 78°F wet bulb).
 

Whaley Towers have a life expectancy of 20+ years.
How does WPI accomplish this? Very simple.
 

WP Series Cooling Tower Features

Construction material details:
frpmaterial
Non-corrosive FRP(Fiberglass Reinforced Polyester) marine grade resins
Surface layer containing pigmented gel coat
Ultraviolet (UV) inhibitor included as an additive to the composite matrix.

Accu-Pac cross fluted fill pack:
ctilogosmallfillmaterial
Improves water distribution by splitting water stream 8 times in a 12″ vertical path as it descends through the fill pack
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC

Accu-Pac counterflow cellular drift eliminators
ctilogosmalldriftmaterial
High surface area provides maximum performance at minimum pressure drop
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC

Cellular Inlet Louvers installed:
ctilogosmalllouver
Improve air flow into cooling tower
Prevent debris from entering
Eliminate water splash-out that can cause icing, water treatment chemical loss
Restricts amount of sunlight into cooling tower impeding algae growth
Reduce noise from tower
Improve tower’s appearance
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC

Lightweight ABS plastic non-clogging Dek-Spray nozzles
nozzles
serviceable at temperatures up to 180F/82C
Results in less system weight & piping cost

Steel Tower platform with fork slots
towerframe
4″ C-Channel
Sheered sheet metal cover with cut-out for bottom tower drain
Painted with gray Macropoxy 646 Fast Cure Epoxy (high solids, high build, polyamide epoxy designed to protect steel and concrete in industrial exposures)

Side or bottom outlet drain
towerdrains
Location and size of outlet fitting determined according to your requirements

Other Features

Schedule 80 distribution header
manifolds
PVC inlet flange
manifold2
½” automatic water makeup
makeupvalve
Stainless steel hardware
hardware
Glossy white color
whitegloss
Direct drive fan motors
towerfanmotorsmall
Axial fan blades
axialbladessmall